ISDS205 dual-channel digital oscilloscope, with "low-cost, high-performance" as the design goals. well-designed bandwidth of 20M, 48M sampling rate, 2 channels, alternating support X-T and XY alternating pattern of two-channel virtual oscilloscope, spectrum analyzer, data recorder.
Digital Oscilloscope |
Channels |
2 |
Impedance |
1MΩ 25pF |
Coupling |
AC/DC |
Vertical resolution |
8Bit |
Gain range |
-6V ~ 6V (probe X1)
-60V ~ 60V (probe X10) |
Vertical accuracy |
±3% |
Timebase range |
1ns-20s |
Input Protection |
Diode, 50Vpk |
Autoset |
Yes(10Hz to 20MHz) |
Trigger Mode |
Auto, Normal and Signal |
Trigger Type |
No, Rising edge, Falling edge,
Rising edge or Falling edge |
Trigger level |
Yes |
Trigger Source |
CH1, CH2 |
Buffer Size |
1MB/CH |
Bandwidth |
20MHz |
Max sample |
48MS/s |
Vertical mode |
CH1, CH2, ADD, SUB, MUL |
Display Mode |
X, Y-T & X-Y |
measurements |
Yes |
Wave save |
Osc(Private), Excel and Bmp |
Spectrum Analyzers |
Channels |
2 |
Bandwidth |
20MHz |
Algorithm |
FFT(18 windows), correlation |
FFT points |
8-1048576/CHN |
FFT measure |
Harmonic(1-7), SNR, SINAD, ENOB, THD, SFDR |
Filter processing |
FIR filter supports arbitrary range of frequency sampling method , and Rectangle, bartlett, triangular, cosine, hanning, bartlett_hanning, hamming, blackman, blackman_Harris, tukey, Nuttall, FlatTop, Bohman, Parzen, Lanczos, kaiser, gaussand dolph_chebyshev, window method design.
IIR filter support "Butterworth", "Chebyshev I", "Chebyshev II", "Elliptic" type of filter design |
Note: The oscilloscope factory calibration, if you are not satisfied with the measurements, canmanual calibration, the specific reference oscilloscope instructions.
Data Recorder |
Channel |
2 |
Impedance |
1MΩ 25pF |
Coupling |
AC/DC |
Vertical resolution |
8Bit |
Gain range |
-6V ~ 6V (probe X1)
-60V ~ 60V (probe X10) |
Sample |
1 channel : 1K~24M Hz
2 channel : 1K~16M Hz |
Save File |
The maximum 4G, recording time associated with the sampling rate |
Note: The specific speed recorder with computer processing speed, and if use high sampling rate, the situation may break.
Logic Analyzer(205C/205X) |
Channel |
16 |
Sample |
8 channel: 250K-24M Hz; 16 channel: 250K-16M Hz |
Sample points |
1M-2GB |
Saleae Logic Logic Analyzer (205C/205X) |
Channel |
8 |
Sample |
25K-24M Hz |
Protocol Analyzer |
Atmel SWI BiSS C SPI I2C CAN UART I2S/PCM DMX-512 JTAG LIN
Manchester 1-WIRE UNI/O Simple Parallel MDIO USB1.1 PS/2 Keyboard/Mouse |
Sample points |
1MB-10TB |
DDS(205B/205X) |
Wave |
Sine, Square(Duty circle variable),Triangle,Up Sawtooth,Down Sawtooth |
Amplitude |
≥9Vp-p(no load) |
Impedance |
200Ω±10% |
Offset |
±2.5V |
Frequency range |
1Hz - 20MHz(Sine), 1Hz - 2MHz(Others) |
Frequency resolution |
1Hz |
Frequency steadiness |
±1×10-3 |
Frequency precision |
±5×10-3 |
Triangular wave linearity |
≥98% (1Hz-10kHz) |
Sine wave distortion |
≤0.8% (1kHz) |
Square wave rising/falling time |
≤100ns |
Square wave duty circle |
1%-99% |
SWEEP |
Sweep range |
Fs Fe |
Sweep time range |
0.1 - 10 s |
Amplitude |
0.5Vp-p - 10Vp-p |
|